ASTM A335 Pipe Specifications |
ASTM A335 Standards specifications download
This specification covers nominal wall and minimum wall seamless ferritic alloy-steel pipe intended for high temperature service. Pipe ordered to this specification shall be suitable for bending, flanging (vanstoning), and similar forming operations, and for fusion welding.
|
|
Grade |
P-5 |
P-9 |
P-11 |
P-22 |
P-91 |
P-91 shall also include the following: |
Element |
UNS Designation |
K41545 |
S50400 |
K11597 |
K21590 |
K91560 |
Carbon |
0.15 max |
0.15 max |
0.05 - 0.15 |
0.05 - 0.15 |
0.08 - 0.12 |
V at 0.18 - 0.25 |
Manganese |
0.30 - 0.60 |
0.30 - 0.60 |
0.30 - 0.60 |
0.30 - 0.60 |
0.30 - 0.60 |
N at 0.030 - 0.070 |
Phosphorous, max |
0.025 |
0.025 |
0.025 |
0.025 |
0.020 |
Ni at 0.40 max |
Sulfur, max |
0.025 |
0.025 |
0.025 |
0.025 |
0.010 |
Al at 0.02 max |
Silicon |
0.50 max |
0.25 - 1.00 |
0.50 - 1.00 |
0.50 max |
0.20 -0.50 |
Cb at 0.06 - 0.10 |
Chromium |
4.00 - 6.00 |
8.00 - 10.00 |
1.00 - 1.50 |
1.90 - 2.60 |
8.00 - 9.50 |
Ti at 0.01 max |
Molybdenum |
0.45 -0.65 |
0.90 - 1.10 |
0.44 - 0.65 |
0.87 - 1.13 |
0.85 - 1.05 |
Zr at 0.01 max |
|
|
Seamless |
|
|
|
|
P-5 |
P-9 |
P-11 |
P-22 |
P-91 |
P91 shall not have a hardness not exceeding 250 HB/265 HV [25HRC]. |
Tensile Strength, min., psi |
|
|
|
|
|
|
ksi |
60 |
60 |
60 |
60 |
85 |
|
MPa |
415 |
415 |
415 |
415 |
585 |
|
|
Yield Strength, min., psi |
|
|
|
|
|
|
|
|
ksi |
30 |
30 |
30 |
30 |
60 |
|
|
|
MPa |
205 |
205 |
205 |
205 |
415 |
|
|
|
P5, P9, P11, and P22 |
|
|
Grade |
Heat Treatment Type |
Normalizing Temperature Range F [C] |
Subcritical Annealing or Tempering
Temperature Range F [C] |
|
P5 (b,c) |
Full or Isothermal Anneal |
|
|
|
Normalize and Temper |
***** |
1250 [675] |
|
Subcritical Anneal (P5c only) |
***** |
1325 - 1375 [715 - 745] |
P9 |
Full or Isothermal Anneal |
|
|
|
Normalize and Temper |
***** |
1250 [675] |
P11 |
Full or Isothermal Anneal |
|
|
|
Normalize and Temper |
***** |
1200 [650] |
P22 |
Full or Isothermal Anneal |
|
|
|
Normalize and Temper |
***** |
1250 [675] |
P91 |
Normalize and Temper |
1900-1975 [1040 - 1080] |
1350-1470 [730 - 800] |
|
Quench and Temper |
1900-1975 [1040 - 1080] |
1350-1470 [730 - 800] |
|
|
|
Contact Us >> |
Phone:
Fax: +86-510-68930106
E-mail: info@magvant.com
Technical communication
tech@magvant.com
www.magvant.com |
|